Only the MASTER control panel can change the identification number (1
through 128) of electronic keys.
To configure a control panel as SLAVE: use a valid electronic key and follow Ad-
dress 421 procedure. SLAVE control panels can program the options of valid
electronic keys only. The factory default programming of the control panel is MAS-
TER.
Options (Addresses 423 to 425)
Addresses 423 and 425 are for Options programming. During Options
programming the keys will take on the meaning shown in the following ta-
bles: Key OFF = option disabled; Key ON = option enabled.
Add. Keys OPTIONS DEFAULT
423 Auto-reset partition no. 1
Auto-reset partition no. 2
Auto-reset partition no. 3
Auto-reset partition no. 4
False Digital Key signalling
Immediate Mains Failure
signalling
Key reader LEDs permanently
active
Telephone line check
u
425 Reset tamper memory denied to
User Code
Reset alarm memory denied to
Installer Code
Arming denied with battery
trouble
Enable Installer Code for User Code
PIN programming via PC
u
Enable Installer
Code PIN for
User Code PIN
programming
via PC
When this option is enabled the Installer can program all the User Code
PINs via PC (the Main User PIN will not be required). However, the In-
staller Code PIN must be entered in the Installer Code page. The words
Freed PIN Programming on the title bar of the PIN Programming window
will flash to signal option enabled.
+
This option can be enabled from the keypad only.
WARNING Use of Freed PIN programming lowers the security level
of the system, and is done at the Installers own risk. The customer
must be informed of the possible consequences.