LEDs STATUS
Arm
off:
ON:
All the enabled partitions on the keypad are
disarmed
At least one Partition enabled on the keypad is
armed
Alarm
off:
slow flashing:
fast flashing:
Standby status (no alarm)
Alarm memory
Alarm status
Trouble
off:
ON:
slow flashing:
No trouble
Trouble: use the Trouble Viewing Mode to identify
the trouble type
Trouble Viewing Mode running
Ready
ON:
off:
Ready to arm: ----arming will not generate an alarm
At least one unbypassed zone is in alarm status: ----
arming will generate an alarm
24h
off:
slow flashing:
fast flashing:
Tamper line balanced
Alarm memorized on the tamper line
Alarm memorized and tamper line open
NOT IN USE
Bypass
off:
ON:
slow flashing
No bypassed zones
At least one of the keypad zones is bypassed
Control panel is ready for zone bypass
Program.
off:
ON:
slow flashing:
fast flashing:
Control panel in standby status
Control panel enabled for Teleservice calls
Control panel in programming status
Control panel in service status (maintenance)
TROUBLE VIEWING MODE
Key 1
off:
ON:
fuse 5 intact
fuse 5 blown
Key 4
off:
ON:
Main Unit powered by mains
mains failure: Main Unit powered by battery
Key 7
off:
ON:
battery charged
low battery or battery trouble
Key A
off:
ON:
communication bus normal
communication bus trouble
Key 0
off:
ON:
telephone line present
telephone line trouble
14 Security System Control Panels Omnia8/Omnia4