Configuration
Setup
Use the check boxes to select the required peripherals (box checked = pe-
ripheral in configuration; box cleared = peripheral not in configuration).
Select the Details button to open the required Details window (Keypads or
Key readers) and program the peripheral parameters, as follows.
no. This is the device address and identifier number.
Description This is the device label (maximum 16 characters). The label will identify the
device in all the actions it is involved in.
Keypads
1 ... 4 Use this row to assign the keypad to the partitions it must control (arm, dis-
arm, etc.).
+
Keypads need not necessarily be assigned to partitions, and can be used
for programming, display and other function purposes.
Key readers
The basic functions of the Control panel can be controlled by inserting a
valid digital key into any key reader, the basic functions are:
Ø Global arming A, B
Ø Disarm partitions
Ø Stop alarm signalling on partitions
Figure 23 Key reader page