Programming structure and modes
Structure The programming phase has two distinct phases ----signalled by LED L6.
PHASE 1 ----ENTER PARAMETER ADDRESS ----LED L6 OFF
Ø Phase 1 ----enter the Address of the parameter to be programmed (maxi-
mum 3 digits) then press .
Access to PHASE 2 will be signalled by a long high-tone beep. Access De-
nied will be signalled by a long low-tone beep. Retry after the error beep.
+
Press to quit the programming phase.
PHASE 2 ----ENTER PARAMETER VALUE ----LED L6 ON
Ø Phase 2 ----enter the value of the parameter then press .
Parameters such as: partition assignment, options, attributes, enable, dis-
able, etc., can be viewed by means of the LEDs under the number keys.
An audible acceptance or error signal will be emitted when the keys are
pressed.
Telephone numbers, PINs, times, etc., cannot be viewed on the keypad,
and the LEDs under the number keys will be OFF.
The entered parameter must match the accepted value e.g. Time = hhmm
(2 digits for the Hour - 2 digits for the Minutes).
Press to step back to PHASE 1.
+
PRESS THE ENTER KEY TO SAVE THE ENTERED PARAMETER
VALUE.
Figure 43 LEDs and keys
86 Security System Control panels Omnia8/Omnia4