Zones
The Omnia8 Main unit has 8 Input zones (terminals [Lx]), whereas, the
Omnia4 Main unit has 4 Input zones (terminals [Lx]).
The zones can be programmed as Alarm or Command zones.
Alarm zones Violation of an Alarm zone of an armed partition (refer to "Partitions") will
activate:
Ø the alarm output (terminals 19-20-21[NO-COM-NC]);
Ø the Alarm zone no. event (no. indicates the zone identifier number). One
or more telephone actions (digital communicator and / or telephone dialler)
can be assigned to this alarm event.
A zone which has generated an Alarm zone no. event must return to
standby status before it can generate another (refer to "Balance types").
Persistent violation of a zone will be signalled by the corresponding key on
the keypad.
The control panel will start monitoring a Delayed zone as soon as its parti-
tion is armed (refer to "Types"), otherwise, monitoring will start when the
programmed Exit delay expires (refer to "Partitions).
An alarm will be generated when the zone is unbalanced for 300 ms (refer
to "Balance types").
Each zone can generate alarm for the programmed number of times (refer
to "Cycles").